Flexible Stranded Conductors for Patch Cords
Our Cat6 Stranded Shielded Cable uses stranded conductors. Each conductor is made of many thin copper strands twisted together. This gives much better flexibility than solid cable. This is critical for patch cords. They get bent, pulled, and plugged in daily. A solid cable can break inside after repeated flexing. But our product handles this easily. It stays strong through constant use in data center racks. Our cable has an aluminum foil shield. This blocks outside electromagnetic interference. If your site has big motors, variable drives, or many wireless devices, unshielded cables drop packets. Our product fixes this problem. Sales keep rising as more data centers care about airflow and space. Soft, thin cables route neatly and do not block cooling channels. This saves energy costs.
Oxygen-Free Copper with Full Testing
Our Cat6 Stranded Shielded Cable uses 100% oxygen-free copper. It is 23 AWG stranded. It runs at 250 MHz bandwidth. It meets ANSI/TIA-568-C.2 and ISO/IEC 11801 standards. We test every reel for continuity and attenuation before shipping. At this price point, our product offers unbeatable value. We have ISO9001, ISO14001, and ISO45001 certifications. We support third-party testing by a lab you choose. The cable works from -20°C to +70°C. Jacket options are PVC or LSZH. Choose single foil or foil with braid shield (please discuss with us). We support OEM orders. We print your brand and package your way.
Custom Lengths and Quick Shipping
We cut our Cat6 Stranded Shielded Cable to your length. It comes on reels or in boxes. We cover it with PE film to keep dust out. We print your logo and specs on cartons. Shipping is by sea, air, or courier. Orders usually ship in about 15 working days. This cable is ideal for data center patch cords, factory floors, and substations. It works for equipment connections and PoE setups. Use it where the cable bends a lot - under raised floors or inside small cable trays. For shielded cable, remember to use shielded plugs and proper grounding. Otherwise the shield does not work well. Please ask us for MOQ. Custom lengths and colors are available. We confirm final specs with a sample before production.
Specifications
|
Parameter |
Specification |
|
Product Standard |
ANSI/TIA-568-C.2, ISO/IEC 11801 |
|
Category |
Cat6 (Shielded) |
|
Shielding Type |
F/UTP (Foil Shield) |
|
Conductor Material |
100% Oxygen-Free Copper (Stranded) |
|
Conductor Gauge |
23 AWG (Stranded) |
|
Insulation Material |
HDPE |
|
Jacket Material |
PVC or LSZH |
|
Frequency |
Up to 250 MHz |
|
Operating Temperature |
-20°C to +70°C |
|
Impedance |
100 ± 15 Ω |