Cat6 Riser Solid Cable

Cat6 Riser Solid Cable

The cat6 riser solid cable is a Category 6 riser-rated Ethernet cable. It is made for vertical shaft backbone wiring. It uses 23AWG solid bare copper and a CMR flame-retardant PVC jacket. It runs Gigabit at 100 meters. This product is a standard choice for floor-to-floor Gigabit backbone in offices, schools, and residential buildings. It is good for non-plenum vertical installation.
Send Inquiry
Description
Technical Parameters

What This Cable Is

 

 

The cat6 riser solid cable is a Category 6 riser-rated Ethernet cable. It is made for vertical shaft backbone wiring. It uses 23AWG solid bare copper and a CMR flame-retardant PVC jacket. It runs Gigabit at 100 meters. This product is a standard choice for floor-to-floor Gigabit backbone in offices, schools, and residential buildings. It is good for non-plenum vertical installation.

 

Where It Fits

 

 

Buyers first check the building type and shaft location. This cat6 riser solid cable fits vertical weak current shaft floor backbone wiring in multi-floor buildings. It fits school teaching buildings, office buildings, and residential floor interconnects. It fits data center aggregation to access layer links. It fits CMR-rated vertical cabling systems. It also fits fixed installation of Gigabit backbone links. This product works with standard RJ45 modules and patch panels. The table below shows the main fit points.

 

Compatibility Item

Details

Installation Area

Vertical shaft, weak current shaft, building backbone

Conductor Type

23AWG solid bare copper

Insulation

Foam-skin polyethylene, Foam-Skin PE

Flame Rating

UL1666 Riser, CMR

Pair Structure

4 pairs, 8 cores, PE cross separator

Connector Type

Standard RJ45 modules and patch panels

Max Frequency

250MHz

Data Rate

1Gbps at 100m

 

 
 
Technical Specifications

 

The cat6 riser solid cable uses 23AWG solid bare copper. DC resistance stays below 7.5Ω/100m. It meets all TIA/EIA-568-C.2 Class E electrical requirements at 250MHz. Insulation uses foam polyethylene. A cross separator keeps the four pairs apart. The structure is stable. During vertical installation, the cable stretches under its own weight. Pair spacing does not change much. The jacket uses UL1666 flame-retardant PVC. Outer diameter is 6.2mm ± 0.3mm. Each box of product is tested across 250MHz before shipment. Tests cover near-end crosstalk, return loss, insertion loss, and propagation delay. The standard package is 305 meters per box. The outer box marks product information, flame rating, and test result.

 

Parameter

Specification

Conductor Material

Oxygen-free copper, purity ≥99.95%

Conductor Size

23AWG, solid bare copper

Insulation

Foam-skin polyethylene, Foam-Skin PE

Jacket Material

Flame-retardant PVC, CMR rated

Flame Rating

UL1666 Riser

Pair Structure

4 pairs, 8 cores, PE cross separator

Outer Diameter

6.2mm ± 0.3mm

Characteristic Impedance

100Ω ± 15Ω

Max Transmission Frequency

250MHz

Data Rate

1Gbps at 100m

Operating Temperature

-20°C to +75°C

Max Installation Tension

≤110N

Standard

TIA/EIA-568-C.2, ISO/IEC 11801 Class E

Standard Package

305m/box, 1000ft

 

How to Choose the Right Model

 

 

Buyers often need color and packaging options for the product. We support color customization. Gray is the standard color. Other colors need 50 boxes. The jacket can print your brand and meter marks. Length options include 305m per box and 500m wooden reel packages for large projects. Flame rating can change to CMP if needed. This product is a good choice for Gigabit vertical backbone. Samples ship in 7 working days. Bulk orders take 15 working days.

 

Quality Testing and OEM Support

 

 

We test each batch of cat6 riser solid cable across 250MHz. The product meets TIA/EIA-568-C.2 and ISO/IEC 11801 Class E. Tests cover near-end crosstalk, return loss, insertion loss, and propagation delay. We also check conductor resistance and jacket thickness. For OEM orders, you can customize color, print, length, and flame rating. If you need a quote, send us your building type, shaft height, cable length, color, and flame rating.

 

FAQ

 

 

Q1: What is the difference between cat6 riser solid cable and cat6 plenum solid cable besides the jacket?

A1: The conductor, insulation, and cross separator are the same. The only difference is jacket material. CMR is flame-retardant PVC for non-plenum vertical shafts. CMP is low smoke zero halogen material for air duct areas. The installation area decides the choice.

Q2: Can Cat6 CMR cable be used for horizontal cabling?

A2: Yes, as long as the area is not an air duct or return air plenum. CMR works for horizontal cabling. Horizontal cabling usually uses lower CM rating. CMR performs better but costs a little more. Choose the rating based on project fire code and budget.

Hot Tags: cat6 riser solid cable, China cat6 riser solid cable manufacturers, suppliers, factory, Category 6 Cable, ethernet cable security, fiber optic cable rj45 connector, in cable network, other cable options, wireless ethernet cord