Product Overview
Category 3 Patch Panel (110 Type | 100 Pairs | 24-26AWG)
Type: Category 3 voice 110 patch panel, 4-pair/5-pair 110 connecting blocks, Whiteunshielded construction.
Application: voice backbone cabling, PBX port breakout, and telecommunications-room cross-connects.
Technical Specifications
|
Item |
Parameter |
Item |
Parameter |
|
Structure Type |
110-type patch panel |
connection capacity |
100 pairs |
|
Shielding Type |
Unshielded |
Color |
White |
|
Connecting Blocks |
4-pair/5-pair 110 connecting blocks |
Termination Method |
110 punch-down termination |
|
Overall Material |
ABS plastic |
IDC Material |
Nickel-plated phosphor bronze |
|
Applicable Wire Gauge |
24-26AWG |
IDC Termination Cycles |
>=200 cycles |
|
Installation Temperature |
0~+60℃ |
Operating Temperature |
-20~+60℃ |
|
Labeling Method |
Replaceable color label paper |
Applicable System |
Voice backbone cross-connect |
Compatibility
- Compatible with 19-inch RJ45 cabinet cabling environments used with Cisco, HPE, Huawei, and similar equipment.
- Supports T568A / T568B termination standards.
- Can connect horizontal cables, patch cords, switches, and cabinet cabling systems.
- Recommended for use with Cat3 modules, patch panels, and RJ11 / RJ45 termination components to maintain link-grade consistency.

Link testing or outgoing random inspection can be provided based on project acceptance requirements.
Performance Parameters
- Data Rate: Supports voice communication and 10Mbps low-speed data transmission.
- 10G / 40G Assessment: Not intended for 10G / 40G high-speed network projects.
- Fluke Test: After termination, the complete link can be Fluke tested.
- Attenuation: Confirmed by complete-link test results; port termination quality affects loss.
- Crosstalk: Port spacing, IDC termination, and pair untwist length affect crosstalk performance.
Materials & Construction
- Panel Material: Cold-rolled steel or metal panels with surface coating can be used.
- Termination Structure: Cat3-grade RJ45 ports and IDC terminals, suitable for terminating corresponding-grade 99.99% pure-copper Ethernet cables.
- Label Structure: Port numbers, replaceable label strips, or cable management brackets can be configured.
- Matching Cable: Can be used with LSZH jacketed cables for cabinet and indoor project cabling.

- Packaging: Individual carton, foam protection, outer carton, and pallet packaging are available.
- Accessory Packaging: Screws, label strips, or cable management accessories can be included in the box.
- MOQ: Standard port specifications can be ordered by unit or full carton.
- Custom MOQ: Special port count, color, labels, or OEM packaging orders are confirmed by project quantity; custom projects can be discussed for requirements of RMB 200,000 or above.
Installation & Use
- Installation: Supports 19-inch cabinet or rack mounting.
- Pre-terminated: Can be used with pre-terminated modules, patch cords, or project-based kit solutions to reduce on-site termination work.
- Termination Standard: Use either T568A or T568B consistently during installation and keep port numbering consistent.
- Installation Notes: Horizontal cables entering the patch panel should be fixed and managed to avoid port strain.
- Installation Check: After completion, check wiring sequence, continuity, port labels, and link test results.
Lead Time & Supply Capacity
- In-stock Availability: Common port specifications are usually in stock for replenishment and urgent projects.
- Production Lead Time: For items not in stock, production usually takes approximately 10 working days.
- Custom Lead Time: For port count, category grade, color, label, or OEM packaging requirements, lead time is confirmed based on order quantity and production schedule.
- Shipment Confirmation: Inventory quantity, packaging method, and estimated dispatch time can be confirmed before ordering.
- Supports 100-pair 110-type voice patch panel configuration
- Supports label paper, port numbering, and color-coding customization
- 4-pair or 5-pair connecting block options can be selected according to the project
- Supports packaging, logo, and project numbering customization
- Can be supplied with Category 3 patch cables, voice modules, and cabinets

Applications
- PBX port breakout
- voice backbone and floor voice distribution
- voice cross-connects in telecommunications rooms and equipment rooms
Quality & Certifications
Internationally certified quality systems support reliable cabling products for network, communication, and security projects.

ISO9001

ISO14001

ISO45001

CCC Certification – AVAVRAVVRRVVP

CCC Certification – BVRVBVR

CCC Certification – RVVRSRVB
Frequently Asked Questions
What is the Category 3 Patch Panel mainly used for?
-
It is mainly used for voice backbone and telephone system cross-connects.
Is it an RJ45 patch panel?
-
No. This is a 110-type patch panel using 110 punch-down connections.
What is the connection capacity?
-
The standard connection capacity is 100 pairs.
What wire gauge is supported?
-
It is suitable for 24-26AWG cables.
Are the labels replaceable?
-
Yes. label strip inside Replaceable color label paper.