CMR-Rated for Vertical Riser Applications
Our Cat6 Plenum Rated Cable is often confused with Plenum cable. Let us explain the difference. Plenum (CMP) is the highest grade for air ducts. Riser (CMR) is the next grade. It is for vertical shafts between floors. For example, from the telecom room to each floor. If your project does not have return air spaces, CMR is enough. It costs much less than CMP. Our Cat6 Plenum Rated Cable uses CMR-grade jacket material. It passes UL 1666 vertical flame tests. In a fire, this cable does not spread flames quickly. This is critical in high-rise buildings. The riser shaft goes straight up. A fire there spreads like a chimney. Our cable stops that risk.
Solid Copper with Full Riser Compliance
Our Cat6 Plenum Rated Cable uses 23 AWG solid bare copper conductors. It has a plastic cross-frame inside. It holds the four twisted pairs to cut crosstalk. It runs at 250 MHz bandwidth. It meets ANSI/TIA-568-C.2 and ISO/IEC 11801 standards. The jacket is flame-retardant PVC. It passed UL 1666 vertical burn tests. We can provide test reports and certificates. Our Cat6 Plenum Rated Cable is for high-rise buildings, hotels, hospitals, and schools. Any project with fire inspection requirements needs this rating. We often tell our customers: spending a little more on the right cable is cheap. Buying the wrong cable can cost 10 times more in rework. Failed fire inspections delay the whole project. Our cable gives you confidence.
OEM Support and Standard Shipping
Our Cat6 Plenum Rated Cable supports OEM orders. We print your brand on cartons and cable jackets. Lengths and colors are customizable. Standard lengths or custom cutting available. We pack in boxes or on reels. We ship by sea, air, or courier. Normal orders ship in 15 working days. This cable is for vertical riser wiring between floors, office buildings, hotels, hospitals, data center non-plenum areas, and any building with fire code requirements. It is not for open air plenums - use CMP for that. Choose the right grade for your project. Please ask us for MOQ. Tell us your needs early. We provide UL test reports and fire rating certificates. Our team can help you select the correct fire rating for your application.
Specifications
|
Parameter |
Specification |
|
Product Standard |
ANSI/TIA-568-C.2, ISO/IEC 11801 |
|
Category |
Cat6 |
|
Jacket Rating |
CMR (Riser-Rated) |
|
Flame Standard |
UL 1666 |
|
Conductor Material |
100% Solid Bare Copper |
|
Conductor Gauge |
23 AWG |
|
Conductor Diameter |
0.57 mm |
|
Insulation Material |
HDPE |
|
Cross-Frame |
Yes |
|
Frequency |
Up to 250 MHz |
|
Jacket Material |
Flame-Retardant PVC |